Commissioning
© Festo Didactic • MPS
®
PA Compact Workstation
49
5.3.5
EduTrainer Festo CPX-FEC IT and MPS
®
PA Compact Workstation
EduTrainer CPX-FEC and Touchpanel FED500 in mounting frame
All cable connections are described as an example for a EduTrainer Festo CPX-FEC IT
with the Compact Workstation.
•
CPX-FEC – station: connect the XMA plug of the PLC /controller with the XMA1
socket of the I/O terminal (2) of the station with a SysLink cable (3).
•
CPX-FEC – station: connect the analog plug of the PLC /controller with the X2
socket of the analog terminal (4) of the station
with the analog cable (5).
•
CPX-FEC – power supply unit: connect 4 mm safety plugs (red, blue and yellow) of
the PLC /controller to power supply unit
with 4 mm safety plugs cable (red = + / blue = — /yellow = ground).
•
CPX-FEC – PLC: Connect your PC to the PLC by means of a programming cable. For
usage of visualization please connect PLC and PC via Ethernet cable (crossover)
or connect both to an Ethernet switch or network.