Festo — CPX-AP-A-EC-M12 — 2022-07
Parameterisation
17
Index
Description
Value
0x27F0
AP parameter access
Parameter query from AP modules
0x27F1
Stored parameters NV
Supports saving of the system (expansion
and parameters) in the bus node
0x6000
…
0x6FFF
Input data object area
Input objects (TxPDOs)
0x7000
…
0x7FFF
Output data object area
Output objects (RxPDOs)
0x9000
…
0x9FFF
Information data object area
Module information
0xA000
…
0xA1FF
Module diagnostics area
Reading out the current diagnostics status
and last error from the modules.
0xF000
Modular device profile object
Tab. 19 Modular device profile object
0xF030
…
0xF03F
Configured module ident list
Tab. 20 Configured module ident list
0xF050
…
0xF05F
Detected module ident list
Tab. 21 Detected module ident list
Tab. 13: EtherCAT Modular Device Profile
ISDU Access (0x22xx)
Sub-
index
Data type
Description
0
UNSIGNED8
Number of subindexes = 7
1
UNSIGNED8
Access:
–
0 = read
–
1 = write
Writing to this subindex defines the data transfer
2
UNSIGNED8
Channel (starting with 0)
3
UNSIGNED16
ISDU index from the IO-Link device
4
UNSIGNED8
ISDU subindex from the IO-Link device
5
UNSIGNED16
ISDU Error