24
Festo — CPX-AP-A-EC-M12 — 2022-07
Diagnostics and fault clearance
ID hex (dec)
Message
Description
06 | 00 | 0188
(100663688)
Modulidentification
check skipped
Ident check skipped - PLC has not written to Object
0xF030
Remedy
–
Download slot configuration
Diag-
nostic
status
Warning
06 | 00 | 0189
(100663689)
Modulidentification
check failed
Ident check failed for configured module at slot %u
(Detected %u - Configured %u)
Remedy
–
Download updated slot configuration
Diag-
nostic
status
Error
08 | 00 | 012E
(134218030)
Device address
invalid
The address, which was assigned to the device is invalid.
Remedy
–
Verify address configuration settings. Is the
address assigned by software or set by
hardware (dip switch).
–
Check the assigned address of the device.
–
Check for multiple address assignment of
the same address.
–
Check dip switch setting.
Diag-
nostic
status
Warning
08 | 00 | 0192
(134218130)
Invalid cycle time
Calculate bus cycle time failed (Local timer too slow)
Remedy
–
Increase cycle time
Diag-
nostic
status
Error
08 | 01 | 0124
(134283556)
AP master lost
No communication with AP master possible.
Remedy
–
Restart AP master.
–
Check communication cable (AP)
Diag-
nostic
status
Error
08 | 01 | 0127
(134283559)
AP Module Discon-
nected
The AP system communication to a module has failed.
Remedy
–
Restart AP system.
–
Check communication cable (AP)