28
Festo — CPX-AP-A-EC-M12 — 2022-07
Diagnostics and fault clearance
ID hex (dec)
Message
Description
08 | 04 | 0196
(134480278)
DC activation register
invalid
Diag-
nostic
status
Error
08 | 04 | 0197
(134480279)
SyncType not sup-
ported
Configured SyncType (0x1C32.1 or 0x1C33.1) not sup-
ported. Check DC registers and supported SyncTypes
(0x1C32.4 and 0x1C33.4)
Remedy
–
Check DC registers and supported Syn-
cTypes (0x1C32.4 and 0x1C33.4)
Diag-
nostic
status
Error
0A | 01 | 00F9
(167837945)
Error RTE module
watchdog monitoring
Error RTE module watchdog monitoring triggers
Remedy
–
Restart device
–
Perform firmware update
–
Service case
Diag-
nostic
status
Error
0B | 00 | 0140
(184549696)
Systemstart
The system is starting.
Remedy
–
None
Diag-
nostic
status
Information
0B | 04 | 00B7
(184811703)
Firmware invalid
Firmware invalid
Remedy
–
Repeat transfer of firmware package.
Diag-
nostic
status
Error
0B | 08 | 018F
(185074063)
Unsupported Version
of full diagnostic
image
The version of the full diagnostic image is not supported.
Remedy
–
Check firmware versions of master and
devices and update to compatible versions.
Diag-
nostic
status
Error
0B | 08 | 0190
(185074064)
Unsupported Version
of diagnosis
The version of the diagnosis is not supported.
Remedy
–
Check firmware versions of master and
devices and update to compatible versions.