6 / 20
Festo 7Tension01_TBb_en
1.3
General safety information
Warning
The toothed belt pretension must only be set by authorised and trained persons in accordance with the specifications
in the technical documentation.
Setting of the toothed belt pretension by persons without the necessary authorisation and training as well as without
the technical documentation required is dangerous and therefore not permitted.
Setting of the toothed belt pretension using the toothed belt pretension test equipment must only be carried out in
conjunction with these operating instructions as well as the respective repair instructions for the device.
Environment
Components and equipment replaced as part of a repair must be disposed of in accordance with the locally valid envi-
ronmental protection regulations.
2
Control elements and connections
2.1
Test equipment
6 7 8
1
2
3
4
5
9
aJ
aA
aC
aD
aE
aF
aB
1
Position stop for DGE-25/40/63
2
Extension sleeve 10 mm
3
Stop bolt 8 × 22 mm
4
Extension sleeve 25 mm
5
Slide mechanism, indexing by means of spring
pressure elements
6
Measurement head holder for acoustic
belt tension meter
7
Plunger with 2-spring package
8
Plunger housing
9
Clamp piece for DGE-25-ZR-RF
aJ
Stop bolt 13 × 22 mm
aA
Clamp piece for DGE-40-ZR-RF
aB
Stop bolt 11 × 22 mm
aC
Knurled screw for securing the
position stop
aD
Test equipment
aE
Recesses for the elastomer buffers
aF
M5 threaded holes for the stop bolts
2.2
Mounting kit for ELGA-TB
2
3
7
1
6
4
5
1
Position stop bolt
2
Position stop, left
3
Position stop, right
4
Distance piece for ELGA-TB-G-120
5
Distance piece for ELGA-TB-G-80
6
Distance piece for ELGA-TB-G-70
7
Transport holder for distance pieces