Control interfaces
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
73
3.5.2
Required digital inputs/outputs with a fieldbus activation
The connection diagram shows the required digital inputs for drive enable and movement via the field-
bus.
CMMS/CMMD
9
21
22
10
24 V DC
Controller enable (DIN5)
Output stage enable (DIN4)
Limit switch 0 (DIN6)
2)3)
Limit switch 1 (DIN7)
2)3)
Stop (DIN13)
15
X1/X1.1/X1.2
6
Load “DIN/DOUT” / GND 24 V
EXT/EXT1
X4
X5
CANopen/DriveBus
RS485
PROFIBUS DP/DeviceNet
1)
1)
Interface module CAMC-... (optional)
2)
The limit switches are set by default to N/C contact (configuration over FCT)
3)
Only required for applications with limited positioning range or homing methods with limit switch.
Fig. 3.14 Connection: Required digital inputs/outputs with fieldbus control