![Festo CMMD-AS series Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_description_2283098116.webp)
6
Positioning mode
116
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
6.4.2
Connection: Digital inputs/outputs
The connection diagram shows the required digital inputs for the direct mode.
CMMS/CMMD
9
21
22
10
24 V DC
Controller enable (DIN5)
Output stage enable (DIN4)
Limit switch 0 (DIN6)
2)3)
Limit switch 1 (DIN7)
2)3)
Stop (DIN13)
1)
15
X1/X1.1/X1.2
X4/X5/EXT/EXT1
...
6
Load “DIN/DOUT” / GND 24 V
Fieldbuses
1)
The digital input (DIN13) is used as an analogue input (#AIN0) in speed, force or torque mode.
2)
The limit switches are set by default to N/C contact (configuration over FCT)
3)
Only required for applications with limited positioning range or homing methods with limit switch.
Fig. 6.4
Connection: Required digital inputs/outputs with fieldbus control
Содержание CMMD-AS series
Страница 245: ......