2
Interfaces
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
35
Interface
Function
Page
1
Mains supply
2
Power switch
3
Fuse “control section”
Application-dependent
4
Fuse “power section”
Application-dependent
5
Power supply unit “control section”
Output voltage: 24 V DC
6
External braking resistor
(optional)
–
Resistance
≥
100 Ω
–
Rated output
≤
100 W
–
Pulse power
≤
1600 W
–
Nominal voltage 400 V AC
7
Motor controller CMMD-AS-C8-3A
Protective earthing
“
(housing)
12
Power supply [X9]
–
Power section: 230 V AC (L1/N/PE)
–
Control section: 24 V DC (24 V/0 V)
–
External braking resistor (ZK+/BR-CH)
Motor interfaces [X6.1/X6.2]
–
Motor (U/V/W/PE)
–
Holding brake (BR+/BR–)
–
Motor temperature sensor (MT+/MT–)
Motor encoder [X2.1/X2.2]
–
EnDat interface
Terminal “motor cable screening GND”
(connected with protective earthing
“
)
8
Motor encoder (closed loop)
EnDat interface
12
9
Servo motor EMMS-AS
–
Motor (U/V/W/PE)
–
Holding brake (BR+/BR–)
–
Motor temperature sensor (MT+/MT–)
12
Tab. 2.10 Overview: Power supply, motor and motor encoder interfaces