7
Speed mode and force/torque mode
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
189
7.2.3
Connection: Analogue and digital I/O modules
The connection diagram shows the required digital inputs for the force/torque mode.
Analogue load (AGND), reference potential “reference
voltage output/analogue inputs”
24 V DC
Controller enable (DIN5)
Output stage enable (DIN4)
Limit switch 0 (DIN6)
1)
Limit switch 1 (DIN7)
1)
Common error (DOUT3)
2)
Analogue input, differential (#AIN0)
Screening (SGND)
Controller ready for operation (DOUT 0)
Motion complete (DOUT1)
2)
Start confirmed (DOUT2)
2)
CMMS/CMMD
X1/X1.1/X1.2
12
9
21
22
10
14
2
15
1
24
13
25
Setpoint value:
-10…+10 V
Load “DIN/DOUT” (GND 24 V)
6
4
Reference voltage output (VREF
OUT
), +10 V DC
Analogue input, differential (#AIN0)
1)
The limit switches are set by default to N/C contact (configuration over FCT)
2)
Default setting, freely configurable in the Festo Configuration Tool (FCT).
Fig. 7.7
Connection: Analogue and digital inputs/outputs