![Festo CMMD-AS series Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_description_2283098114.webp)
6
Positioning mode
114
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
6.2.2
Record selection (positioning record) – control interface – operating mode
The selection of the record selection/positioning record is dependent on the control interface and oper-
ating mode:
Control interface
Operating mode
Individual record
mode
Record linking
mode
Homing mode
Teach mode
CANOpen
Record selection/
positioning
record 1…63
Record selection/
positioning
record 1…63
Record selection/
positioning
record 0
Record selection/
positioning
record 1…63
PROFIBUS DP
DeviceNet
Digital inputs
page 49
Mode 0
–
Record selec-
tion bit 1…5
–
Positioning re-
cord 1…63
page 121
Mode 2
–
Record selec-
tion bit 1…2
–
Positioning re-
cord 1…7
page 138
Mode 0
–
Record selec-
tion bit 1…5
–
Positioning re-
cord 0
page 156
Mode 1
–
Record selec-
tion bit 1…5
–
Positioning re-
cord 1…63
page 179
Tab. 6.1
Overview: Record selection (positioning record) – control interface – operating mode
6.3
Relative positioning
The motor controller calculates internally with 65536 increments (16 bit) per revolution (360°). For
positioning tasks that do not have a whole number (integer) as the result, the motor controller rounds
up to the next whole number. This can result in deviations when positioning.
Example: Rotary indexing table
4 positions. (90°) 65536:4= 16384 ----> Integer
6 positions. (60°) 65536:6= 10922.666 ----> The controller positions at 10923 (60.0018°).
Содержание CMMD-AS series