Error group 70
Operating mode error
No.
Code
Message
Reaction
70-2
6195h
General arithmetic error
PS off
Cause
The fieldbus factor group cannot be calculated correctly.
Action
•
Check the factor group.
70-3
6380h
Operating mode
configurable
Cause
This operating mode change is not supported by the motor control-
ler.
Action
•
Check your application.
Not every change is permissible.
Error group 76
SSIO error
No.
Code
Message
Reaction
76-0
8100h
Error SSIO communication (axis 1 - axis 2)
configurable
Cause
Only CMMD-AS:
–
Checksum error during transfer of the SSIO protocol.
–
Timeout during transmission.
Action
•
Check wiring.
•
Check whether the screening of the motor cables is correctly
applied (EMC problem).
If SSIO communication is not absolutely necessary (e.g. no field-
bus interface is used, and the axes are controlled separately over
I/Os), this error may be ignored.
76-1
8100h
Error SSIO communication (axis 2)
configurable
Cause
Only CMMD-AS:
SSIO partner has error 76-0.
Action
The error is triggered when the other axis has reported an SSIO
communication error. For example, if axis 2 reports the error 76-0,
the error 76-1 is triggered for axis 1.
Measures and description of the error response as with error 76-0.
Error group 79
RS232 error
No.
Code
Message
Reaction
79-0
7510h
RS232 communication error
configurable
Cause
Overrun when receiving RS232 commands.
Action
•
Check wiring.
•
Check of the transmitted data.