4
Mounting and installation
Festo – GDCP-CMCA-INST-EN – 1211a – English
31
Key actuator “brake release”(S3)
Terminal strip
Terminal
Description
X2
225
Pin 13, (S3)
X6
618
Pin 14, (S3)
Tab. 4.16
4.2.9
Operating mode selection
Terminal strip
Terminal
Terminal
Description
X6
611
612
With the key actuator (S2), you can select locally
between the manual operation and automatic opera-
tion modes (status on delivery)
614
615
611
610
With the external higher-order controller, you can
select locally between the manual operation and
automatic operation modes
614
613
Tab. 4.17
Fig. 4.6
Operating mode selection, external
Fig. 4.7
Operating mode selection, local
Operating mode selection by means of higher-order controller
If the operating mode selection is made through a higher-order controller, you must make two poten-
tial-free relay contacts available there.
Terminal strip
Terminal
Description
X2
224
+24 V DC
X6
610
Manual operation
613
Automatic operation
Tab. 4.18
Note
As supply voltage for these contacts, the supply for terminal X2-224 must be used