4
Mounting and installation
Festo – GDCP-CMCA-INST-EN – 1211a – English
33
4.2.12
Rod loss detection (only for rod kinematic system EXPT)
The pressure switch SDE5 for rod loss detection is connected to the terminal strip X2.
Setting and adjustment of the rod loss detection (
Commissioning description).
Terminal strip
Terminal
Description
X2
208
Supply voltage 0 V DC
228
Supply v24 V DC
211
Signal from the pressure switch for rod loss detection
Tab. 4.20
4.2.13
Connect axis of rotation reference sensor
An optional axis of rotation reference sensor can be connected as follows.
Terminal strip
Terminal
Description
X4
455
Reference sensor signal (at DIN9 motor controller of the last axis)
X2
206
Supply voltage 0 V DC
225
Supply v24 V DC
Tab. 4.21
4.2.14
Connect the camera system supply
The following connections are reserved for the power supply of a camera system (24 V DC).
Terminal strip
Terminal
Description
X2
201
0 V DC
221
+24 V DC
Tab. 4.22
4.2.15
Connect lighting
The following connections are reserved for the power supply of an illumination device (230 V AC), e.g.
for the camera system.
Terminal strip
Terminal
Description
X1
101
230 V AC
1)
N3
0 V AC
1)
Protected through fuse F11
Tab. 4.23