4
Mounting and installation
30
Festo – GDCP-CMCA-INST-EN – 1211a – English
4.2.8
Connect operating and signal elements (with mounting plate design)
Note
These components are already connected in the control switch design.
In the mounting plate design, these components must be connected by the installer.
Illuminated button “quit emergency stop” (S20/P20)
Terminal strip
Terminal
Description
X3
306
Connection 13 (S20)
X6
600
Connection 14 (S20)
X6
601
+24 V DC, (P20)
X2
207
0 V DC, (P20)
Tab. 4.11
Indicator light “external emergency stop” (P21)
Terminal strip
Terminal
Description
X6
602
+24 V DC, (P21)
X2
205
0 V DC, (P21)
Tab. 4.12
Indicator light “automatic control” (P4)
Terminal strip
Terminal
Description
X2
210
0 V DC, (P4)
X6
616
+24 V DC, (P4)
Tab. 4.13
Key actuator “automatic/manual” (S2)
Terminal strip
Terminal
Description
X6
615
Pin 12, (S2)
X2
224
Pin 11, (S2) (connect via S2:13)
Pin 13, (S2)
X6
612
Pin 14, (S2)
Tab. 4.14
Indicator light “manual control” (P5)
Terminal strip
Terminal
Description
X2
210
0 V DC, (P5) (connect via P4:X2)
X6
617
+24 V DC, (P5)
Tab. 4.15