1
Safety and requirements for product use
Festo – GDCP-CMCA-INST-EN – 1211a – English
5
1
Safety and requirements for product use
1.1
Safety
1.1.1
General safety instructions
•
Observe the general safety instructions in the corresponding chapters.
Specific safety regulations can be found immediately before the task instructions.
Warning
Danger of electric shock even if power switch is shut off.
The control system is only completely voltage-free if all supply lines have been switched
voltage-free.
•
Switch off all supply lines (also external voltage) prior to assembly, installation
and/or maintenance work and secure them from being restarted accidentally.
•
Switch the voltage back on only after completion of work.
Note
Damage to the product from incorrect handling.
•
Never pull the plugs and interfaces when powered.
•
Never plug in plugs and interfaces when powered.
•
Observe the handling specifications for electrostatically sensitive devices.
1.1.2
Intended use
The control system CMCA serves to operate a kinematics system in the environment of a machine or
automated systems and must be used as follows:
–
in excellent technical condition
–
in original status, without unauthorised modifications
–
within the limits of the product defined by the technical data (
appendix A.1)
–
in an industrial environment
The safety circuit of the CMCA control solution is only one part of the the safety concept for a machine,
whereby the safety concept must be based on a risk assessment of the entire machine to be performed
by the machine manufacturer.
Note
In the event of damage caused by unauthorised manipulation or other than intended
use, the guarantee is invalidated and the manufacturer is not liable for damages.