4
Mounting and installation
Festo – GDCP-CMCA-INST-EN – 1211a – English
21
4
Mounting and installation
4.1
Mounting
Warning
Danger of injury/damage due to falling loads.
If incorrectly mounted, the control system can become loose and fall.
•
Observe the product weight (
chapter 2.1.1) in selection of the mounting surface
and mounting material (screws, mounting bracket, …).
4.1.1
Mounting plate design CMCA-…-C-…
The control system on the mounting plate must be mounted to the 6 mounting points on a vertical and
sufficiently stable surface.
Mounting points
L3
L1
L2
Fig. 4.1
Dimensions [mm]
L1
925
L2
530
L3
462.5
Tab. 4.1