N U M B E R E R
PAGE 59
M A N UAL
Section 17
ELECTRICAL - SUCTION
The following sections should be used in conjuction with the
troubleshooting section in the operators guide.
17.5 .... Trouble Shooting -
Machine Will Not Run
‘Mains Power on’ Does Not Illuminate.
Check that mains power
of the correct voltage is reaching the machine and rear
isolator. Check that the mains input lead is securely
plugged into it’s socket in the side of the control box.
(remove base access panel to check).
Compressor Does Not Run
If the
Switch does not illuminate
check the connections from the mains inlet socket to the
switch and if sound replace the switch.
If the switch does illuminate, remove the base access panel
and check the compressor lead is securely plugged into it’s
socket in the side of the control box. Check the connections
between the switch and the socket and check the mains
voltage at the compressor motor.
Finally check that compressor is not seized by rotating the
fan on top of motor before replacing the unit. -
WARNING
DON’T DO THIS WITH THE POWER ON.
'
System' switch will not latch
Check that the guards are
correctly closed and the emergency stop switch is released
by turning it counter clockwise. Check the security of both
2 way plugs at the rear of the control box and check both
motor and control fuses.
Check the continuity through each 2 way plug and if not
sound trace the fault to defective connection or switch. If
continuity is sound check the security of connections
between both 2 way sockets and terminals 18 & 19 on the
suction control board (PCB 1). Also check the blue wires at
terminals 22 and 23 on PCB 1.