N U M B E R E R
PAGE 43
M A N UAL
Sensor Installation - Suction Machine........................ Fig 12.12
Section 12
SENSOR
12.2 .... Sensor Replacement
If you need to replace the sensors the diagrams in this section will
help you, as although all machines use the same arrangement, the
wiring to the sensor assemblies follows different routes.
You are advised to replace the sensors as an assembly with their
mounting hardware to ensure correct alignment.
NEVER REPLACE
UPPER OR LOWER UNITS INDIVIDUALLY AS THEY ARE SUPPLIED
AS A MATCHED PAIR.
Take great care when routing the sensor cables as they are fragile
and any damage normally results in failure. Ensure that the cables
are clear of moving parts - particularly around the input rollers -
and that they do not get trapped when fitting covers or closing
Side Frame
(Operator Side)
Upper Tie-Bar
Lower Sensor
Mounting
Upper Sensor
Mounting
Cable Passes
Over Print Position Shaft
Support Shaft
Input Bed
Print Position Shaft
Upper & Lower
Sensor Cables
Upper Sensor
Cable
Lower
Sensor Cable
Cable Ties
Lower Tie Bar