A 941 / AD 941 / AD 951
Fig. 8-11: Calibration of control unit
!
F key
"
Save key (ABS>INC)
#
LED - Inc
8.9.1 Calibration of control unit
The control unit may lose the factory setting during trans-
port. Use the following procedure to calibrate once the
machine is set up:
• Produce a sample workpiece and measure precisely.
• Press F key for about 5 seconds.
• ”REF” and the last calibration are displayed.
• Press ABS>INC (LED flashes)
• Enter the measured value.
• Save the parameter value with the ABS>INC key.
• The calibration value is adopted as the actual value.
!
Actual value display
"
Desired value display
#
Start a position duty
$
Stop a position duty, delete error codes
%
Delete the last input
&
Long operation:
Switch over between parametric level and manual/
fixed value mode.
Short operation:
Manual positioning mode
>> Quick motion up/down
> Creep motion up/down in steps of
0,1 mm/0,005“ steps.
1-3, 4-6
Fixed values
/
ABS>INC:
Switch over between absolute and incremental mode
In parametric level - Modify and store parameter
values.
*
LED - Inc lights up:
The control unit is working in incremental mode.
)
Potentiometer
BL
Switch - ON/OFF feeder switch
8.9 “Digi-Drive” equipment (AD 951)
Fig. 8-10: Digi-Drive
Attention! First decimal place must be entered (e.g. 1-2-0-0 for 120 mm)!
Making adjustments and preparations