IDENTIFICATION
ID ISC.LRU3000 / LRU3500
5 Operating and Display
Elements
Page 22 of 30
Green
Yellow
Red
Description
Configurations-Reset:
FLASH
FLASH
FLASH
While T1 is pushed and hold for at least 5s
(light in sequence)
ON
ON
ON
After T1 has been pushed and hold for 5s. Configuration Reset
has been finished.
Input / Output LED (yellow):
Configurable LED.
Can display the status of a digital input or output
ANT 1
– 4:
Green
HF Power switched on
Blue
Tag-Detect
Red
Antenna impedance error (> 50Ohm or <50Ohm)
5.2 Reset Push Buttons
Figure 19 shows the position of the reset push button’s T1 and T2.
At the right side of the connector X6 the push button T2 is positioned. With this push button a CPU-Reset can
be performed. With the push button T1 within the reader housing on left side of X3 a complete configuration
reset can be performed. For performing a reset you should use a paper clip and push the button T1 for at least
5 s until the 3 status LED’s (left side) are switched on continuously, see
Fig. 19: Position of the reset-switches T1 and T2