IDENTIFICATION
ID ISC.LRU3000 / LRU3500
6 Technical Data
Page 26 of 30
Outputs
2 x Optocoupler
3 x Relay (1 x normal open)
24 V DC
/ 30 mA (galvanically isolated)
24 V DC
/ 1 A (switching current), (2A constant
load)
Inputs
5 x Optocoupler
max. 5-10 V DC
/ 20 mA
Interfaces
RS232, RS485, USB (full Speed), Ethernet, USB
Host, Data-Clock
FUNCTIONAL PROPERTIES
Protocol Modes
FEIG ISO HOST Mode (Advanced Protocol Frame)
Buffered Read Mode
Scan Mode
Notification Mode
Supported Transponder Types
EPC Class 1 Generation 2
ISO 18000-6-C (Upgrade Code required)
further transponder types possible on demand
Optical Indicators
8 LEDs for operating status and diagnostics
Operating System
Linux (64 MB RAM, 256 MB Flash)
Further Features
Anticollision
RSSI
Real Time Clock
RF-Channel monitoring
Antenna SWR monitoring
Temperature Monitoring*
AMBIENT CONDITIONS
Temperature Range
Operation
Storage
-25 °C to +55 °C
-25 °C to +50 °C (only LRU3500 with PoE)
-25 °C to +85 °C
Humidity
5 % to 95 % non-condensing
*
Caution: Overheating of the device may result in performance losses. It is recommended to activate the RF
of the reader only if there is a transponder in the detection range of an antenna.