IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Excellence -A/-B
Installation Gate People
Counter
Page 69 of 69
9 Reader Configuration in Accordance with National RF Regulations
Configuration of the RFID readers and the maximum transmitting power of the antennas are affected mainly
by the country-specific RF regulations. For the entire EU, the limits are set forth in the R&TTE Directive and
EN 300 330.
The ID ISC.ANT1710/690 antenna with the ID ISC.LRM2500 Reader, when used as intended, complies with
the basic requirements of Article 3 and the other relevant clauses of the R&TTE Directive 1999/5/EG of
March 1999. This means that operation in the 27 EU countries and the EFTA countries (EU countries plus
Switzerland, Norway and Iceland) is possible with a maximum field strength of 42 dBµA/m at 10 m distance.
RF approval (at a maximum field strength of 84 dBµV/m at 30 m) for the ID ISC.ANT1710/690 antenna with
ID ISC.LRM2500 Reader has been granted in accordance with FCC Part 15 for the USA and the RSS-210
for Canada.
RF approval in accordance with EN 300 330 is still possible in all 46 CEPT countries.
The CEPT countries are:
Albania (ALB), Andorra (AND), Austria (AUT), Azerbaijan (AZE), Belarus (BLR), Belgium (BEL), Bulgaria
(BUL), Bosnia and Herzegovina (BIH), Croatia (HRV), Cyprus (CYP), Czech Republic (CZE), Denmark
(DNK), Estonia (EST), Finland (FIN), France (F), Germany (D), Greece (GRC), Hungary (HNG), Iceland
(ISL), Ireland (IRL), Italy (I), Latvia (LVA), Liechtenstein (LIE), Lithuania (LTU), Luxembourg (LUX), Malta
(MLT), Former Yugoslav Republic of Macedonia (MKD), Moldova (MDA), Monaco (MCO), Netherlands
(HOL), Norway (NOR), Poland (POL), Portugal (POR), Romania (ROU), Russian Federation (RUS), San
Marino (SMR), Slovak Republic (SVK), Slovenia (SVN), Spain (E), Sweden (S), Switzerland (SUI), Turkey
(TUR), Ukraine (UKR), United Kingdom (G), Vatican City (CVA) and Yugoslavia.
The following restrictions are in effect (as of October 2009):
Outside the EU and EFTA countries RF approval must in all cases be applied for. The existing measuring
protocols in accordance with EN 300 330 are generally sufficient.
When commissioning the antennas, the systems integrator must ensure that the prescribed installation
instructions are followed, that the necessary reader settings are made and that permissible limits according
to national regulations are not exceeded.