IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Excellence -A/-B
Typical Antenna Configuration
Page 49 of 49
3x
3x
7.7 Automatic Bus Addressing
The automatic bus addressing should be done after the setup, configuration and tuning of the gate antennas.
The automatic bus addressing is carried out according to the following conditions:
Step
Action
Note
1
Send a command
[0x64] System Reset
Mode 0x10 Bus Address
in one of the automatic modes
2
Changing the operation mode
from ISO-Host to Buffered Read
or Notification Mode
3
Changing the number of output
channels of the multiplexer if
reader is in one of the automatic
modes.
After the automatic bus addressing the right addressing will be signalized by the LED of the antennas
•
Only LED installed. The LED on the corresponding antenna lights up red.
(Should be number 2 and 3)
•
LED and GPC installed. The LED on the corresponding antenna lights up green.
(Should be number 1 and 4) GPC must be installed in antenna number 4, otherwise the automatic bus
addressing will fail!
•
You might also want to check if the antennas are connected to the right output of the multiplexer.