IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Excellence -A/-B
Typical Antenna Configuration
Page 45 of 45
7.5.3 Reader Setting for Alarm Indicators
The ISOStart software can be used to set the reader configuration so that the output 2 X6-1/-2 opens or
closes or the outputs of the people counter closes when a transponder is read.
Step
Action
Note
1
Start ISOStart Software
2
Select “Configuration” and click on
“Read” to read the complete
configuration.
3
Operating Mode
Select Buffered Read Mode.
4
Digital IO:
Idle Mode: OFF
Idle Flash Mode: 1Hz
Setting Time:
with „Setting Time“ set time of
output 2 for alarm duration.
(10 means 1 second)
(e.g. 10 x 100ms)
Assign Output 2 to antenna 1,2,3
and 4. „True“ means: Output 2 and
will be active if the reader read a
valid transponder.
5
Set by clicking on „Apply“.
6
Peripheral Device
LED Controller:
Setting Time:
„Setting Time“ set the duration time
for the alarm.
(10 means 1 second)
(e.g. 10 x 100ms)
Assign
LEDController Bus Address 11 to
antenna 1-4.
LEDController Bus Address 12 to
antenna 1-4.
......... and so on.
„True“ means: LED with Bus
Address 11, 12, 13, 14 will be
active if the reader read a valid
transponder on the corresponding