When placing the antennas in service, the systems integrator must ensure that the prescribed
mounting instructions are followed, the necessary Reader settings are made and permissible limits
according to the national regulations are not exceeded.
The Reader needs to be configured as follows depending on the installation location:
Parameter
Europe (2) (60dBuA/m)
USA / Europe (1), (42dBuA/m)
General
RF-Power – CFG 3
maximum 10 W
maximum 8 W
Downlink RF Modulation – CFG
20 / RF-Modulation
15%
15%
ISO15693
Downlink RF Modulation – CFG
4 / ISO-MODE / MOD
10%
10%
Downlink RF Data coding –
CFG 4 / ISO-MODE / FAST
Fast (1/4) or Normal (1/256)
Fast (1/4) or Normal (1/256)
Timeslots - CFG 4 / ISO-MODE
/ NO-TS
16 Timeslots
16 Timeslots
Inverntory Command Option –
CFG 4 / ISO-CMD-OPTION /
BREAK
Complete Timeslot length at
„NO TAG“
Complete Timeslot length at