OBID i-scan
®
Installation
ID ISC.ANT1400/760-A/B/C
FEIG ELECTRONIC GmbH
Page 26 of 50
M50700-4e-ID-B.doc
4.2.6 Tuning the Gate Antenna
Before tuning the Gate Antenna you must quit the ISOStart software. Then the gate may be tuned
according to the following sequence:
Step
Action
Note
1
Start “DATuningTool”
Software
2
Click on “Detect Reader...”
button and then “Detect” on
the selected interface (COM-
Port 1)
3
Use „Settings“ to enter the
configuration:
Dual Mode,
Number of Gates 1
Number of Tuning Iterations 3
4
Activate „Start Tuning“ and
wait until the tuning process is
ended.
...
...
5
After each tuning pass the
current tuning status is
displayed.
After successful tuning both
antennas for „Gate 1“ are
shown in green.
After successful tuning close the DATuningTool again.