OBID i-scan
®
Installation
ID ISC.ANT1400/760-A/B/C
FEIG ELECTRONIC GmbH
Page 37 of 50
M50700-4e-ID-B.doc
4.5 Connecting and Setting the Alarm Kit (optional)
The solution provided here presumes that all alarm indicators (LED strip and buzzer) are wired in
parallel and switched through the relay X11 on the ID ISC.LRM2000 Reader. The pulse duration
can be set (CFG2 / REL1) between 100 ms and 6553.5 s by adjusting the Reader configuration.
Relay X11 provides a changeover contact for low voltages.
The alarm indicators must be supplied by the power supply for the Power Splitter or Multiplexer.
4.5.1 Installing the Alarm Indicators
The optical alarm indicator, the Light bar with LED strip, is integrated into the upper frame section.
When installing the antenna this means the standard upper frame section is replaced by the one
having the signal indicator and the LED strip is connected with the connection cable (Fig. 25).
Fig. 24 Screws upper frame
After that the LED strip has to be connected with the connection cable Fig. 25 and the upper frame
has to be mounted to the main antenna frame
Fig. 25: Connecting optical indicators
Screws upper frame
Light bar with LED strip