The indicators are connected as shown in Fig. 28:
Fig. 28: Wiring the indicators
Notes:
All cables must be routed as far from the antenna conductor as possible. Never allow a
cable to contact the copper tube.
All cables should be kept as short as possible. Excess lengths should be shortened or at
least tied together into small loops using cable ties.
The indicators should be powered in any case by a separate power supply independent of
the Reader power supply. A common power supply may cause fault conditions in the
Reader.
The relay outputs are dimensioned for max. 24 V DC / 2 A.
The relay outputs are intended only for switching resistive loads. If an inductive load is used,
the relay contacts must be protected by an external protection circuit.
Reversing the polarity or overloading the outputs will destroy them.
See also Installation Manual ID ISC.LRM2000-A/B
Reader
Buzzer
COM
+24VDC
NO
X9, Pin1+3
GND
DC Power
supply24V
Signal LED
Signal LED 2 (Option BL)