OBID i-scan
®
Installation
ID ISC.ANT1400/760-A/B/C
FEIG ELECTRONIC GmbH
Page 13 of 50
M50700-4e-ID-B.doc
3.3.2 Installing the Antenna Base and Antenna Body
The antenna foot is screwed on the floor. Use the adjusting screws (Fig. 7) to align the antenna
foot vertically.
Adjusting screws (hexagon socket width A/F5)
Fig. 7: Attaching and aligning the antenna foot
The antenna body is connected to the antenna foot and attached to the antenna foot using the
fastening brackets as shown in (Fig. 8). The antenna body may be inserted 180° rotated (Fig. 8) .
Both antennas must installed in the same direction and parallel orientation.
Fig. 8: Connecting antenna base to antenna foot
Fastening brackets
Fastening brackets
Fig. 9: Fastening antenna base to antenna foot