OBID i-scan
®
Installation
ID ISC.ANT1400/760-A/B/C
FEIG ELECTRONIC GmbH
Page 42 of 50
M50700-4e-ID-B.doc
4.5.4 Programming a Transponder with the AFI Byte
If the transponders will remain on the object when leaving the storage location, they must first be
cancelled. This is generally done by writing to a particular area of the transponder.
The AFI byte (Application Family Identifier) is useful for this purpose, since it is contained in nearly
all transponder models in the 13.56 MHz family. To cancel, simply write a different code to the
transponder than for valid transponders which trigger an alarm.
Step
Action:
Note:
1
Select „Commands“
2
Place the Transponder in the
antenna field (Antenna 1)
Select [0x01] Inventory
Select New Inventory
Requested
3
Read UID by clicking on
„Send“
4
The serial number, DSFID
and Transponder type are
displayed in a window.
Write down the serial number
of the Transponder
5
Select „[0x27] Write AFI“
ADR:
1: addressed
Serial Number:
Select Transponder
AFI:
Desired AFI Number (not
equal to 00)
6
Read UID by clicking on
„Send“