OBID i-scan
®
Installation
ID ISC.ANT1400/760-A/B/C
FEIG ELECTRONIC GmbH
Page 31 of 50
M50700-4e-ID-B.doc
4.3.5 Reader
Configuration
To tune the antennas, open the ISOStart software and first read out the current configuration of the
Reader:
Step
Action
Note
1
Start ISOStart Software
2
Run „Detect“...
3
...follow „New-File
Assistant“...
4
...and read out the current
Reader Configuration
Then set the operating power, Transponder Parameters and ISO Host Mode:
Step
Action
Note
1
Select “Configuration”
2
CFG3: RF-Interface
“RF-POWER” (here 8W)
Select “Transponders-Drivers”
(here ISO 15693)
3
Set by clicking on “Write”
4
CFG4:
Transponder Parameters
Configure the parameters as
follows (ISO15693 Mode):
•
„Datacoding“ – 1 of 4
•
„MOD“ – 10%
•
„SUB-CARRIER“ – ASK
•
„DATA-RATE“ – High
•
„NO-TS“ – 1 Timeslot
•
„AFI“ – Disabled
Note: National RF regulations may require different
settings. (see 4.7
Configuring the Reader in accordance
with national RF regulations)
5
Set by clicking on “Write”