Page 1: ...User s Manual I V1 0 0 EAS Acousto Magnetic Antenna User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...

Page 2: ...ult in slight or moderate injury CAUTION Indicates a potential risk which if not avoided could result in property damage data loss reductions in performance or unpredictable results TIPS Provides methods to help you solve a problem or save time NOTE Provides additional information as a supplement to the text Revision History Version Revision Content Release Time V1 0 0 First release July 2021 Priv...

Page 3: ...tween the electronic version and the paper version All designs and software are subject to change without prior written notice Product updates might result in some differences appearing between the actual product and the manual Please contact customer service for the latest program and supplementary documentation There might be errors in the print or deviations in the description of the functions ...

Page 4: ... the device It is recommended to use this device with a surge protection device SPD to improve the lightning protection effect It is recommended to ground the earthing hole of the device to improve device reliability It is recommended to install the device 2 meters away from the escalator to improve device reliability Power Requirements Only use the wire assembly power cable recommended in this ar...

Page 5: ...ons 3 Packing List 3 Installation and Configuration 4 3 3 1 Preparations before You Begin 4 3 3 2 Description of Primary Antenna TX Board Ports and Manual Configuration of Hardware 6 3 3 3 Description of RX Board Ports and Manual Configuration of Hardware 10 Software debugging 11 3 4 1 Software Installation 11 3 4 2 Interface Parameter Description 12 Cybersecurity Recommendations 20 ...

Page 6: ...r power on effective identification system and avoiding more than 95 of external interference sources Reading distance The maximum detection distance of labels is 800 mm 900 mm and the maximum detection distance of tags is 900 mm 1400 mm Invention patent Digital receiving technology High stability without temperature drift which is the core concept of DSP technology High integration Small size sho...

Page 7: ...d detect 58 KHz labels and tags It has strong stability and high detection distance The Acousto Magnetic system includes a primary antenna with two replica antennas no other controllers are needed which makes installation in large supermarkets or multi export venues very convenient Consequently Acousto Magnetic system is regarded as the best choice by various stores and supermarkets Appearance Dim...

Page 8: ... ventilated Pay attention to sun protection waterproof and moisture proof Only be installed by professionals and strictly enforce safety regulations Strictly grounded and powered independently Operating temperature 5 C to 50 C Packing List Table 3 1 Packing list Packing list Image Packing Box Primary antenna Replica antenna Connection cable AC110 Power supply OR AC220 Power supply ...

Page 9: ...xpansion screw 4 Marker 1 Open end wrenches Cutting Machine 1 Hammer 1 Fine sand Scuff plate Power drill 1 Configuration cable 1 Site survey Equipment installation must be at least 2 meters away from large electrical appliances escalators metal panels etc After determining the installation location use a marker to draw lines punch holes and cut grooves Then clean up the site ...

Page 10: ...l 5 Install and fix the equipment Put fine sand in the cutting groove to protect the cables and fill the gaps Next install the scuff plate on the floor Then fix the equipment The equipment installation is complete ...

Page 11: ...nnect remember that cold plug electrical hot plug will cause damage to the TX board Power Port 1 power input port Use the 5 Pin power cord to connect remember that cold plug electrical hot plug will cause damage to the TX board USB Port 1 USB port for software configuration Use the dedicated blue configuration cable to connect CCTV Port 1 Port per antenna Optional not required J201 J301 J401 Corre...

Page 12: ...stem alarm threshold From top to bottom Low Medium High Jumper in L low alarm threshold high sensitivity long detection distance Jumper in M a balanced setting Jumper in H high alarm threshold low sensitivity short detection distance Quick setting of system alarm threshold The alarm threshold of each channel can be individually set by software When a false alarm occurs in the system on site people...

Page 13: ...ou can choose to turn off the transmission of the system when the system is synchronizing with the ambient equipment J108 3 4 Used in conjunction with the system reset button J108 5 6 The signal indicator will locking display the signal strength of the current channel current channel means the channel displayed by the current channel indicator and will no longer cycle ...

Page 14: ... rightmost light is on for channel 1 The second light from the right is on for channel 2 Both lights are on for channel 3 The three rightmost lights in the second row are the indicator lights for channel noise and environmental interference signals light 6 to light 8 If 1 to 2 lights are on it means normal If 3 or more lights are on it means large interference In this case shortening the installat...

Page 15: ...bottom Low Medium High It can be adjusted according to ambient conditions on site and the factory default setting is M When there is a lot of interference on site try to place the jumper in a low gear L to reduce the antenna s ability to sense interference improve the antenna s ability to detect and reduce the false alarm rate RX 1 receiving coil for connecting the antenna LIGHT 1 alarm indicator ...

Page 16: ... Right click on the computer desktop and select My Computer Device Manager Port Use blue configuration cable to connect TX board and computer Port B is for connecting TX board Port A is for connecting computer Configuration cable After finishing the connection of TX board and computer COM interface will appear at software of computer Select Serial port and then click Open All the default parameter...

Page 17: ... 58 6 K Change accordingly to the label s frequency Tx Mode Mode1 Mode1 Mode2 Mode 3 Mode4 Mode5 Change accordingly to the ambient environment mode 1 to mode 3 is available now Tx Power High High Medium Low No need to set up Rx Delay 0 100 No need to set up Slope Rising Rising Falling If there is always jitter between the external phase and system phase when the system is synchronized try to chang...

Page 18: ...threshold When the antenna is prone to intermittent false alarms choose to increase the threshold When setting the threshold in the software make sure that J107 and TX board are disconnected otherwise the setting of J107 will affect the software settings TX ON ON OFF Transmission function on or off RX ON ON OFF Receiving function on or off Set Click this button after changing the parameters Clear ...

Page 19: ...nd upload the calculated phase value Debug Phase Use the mouse to change the phase value so that the upper right corner of the red square and that of black square are on the same line Function Key CH Select the channel to be debugged Refresh Select the corresponding phase channel and click Refresh The antenna will collect the ambient data and upload it to the system for synchronization To facilita...

Page 20: ...nge the phase to a new range click Set otherwise the software will not transmit this value to the machine 3 4 2 3 Phase Sync of Acousto Magnetic System Select the corresponding phase channel and click Refresh The primary antenna will collect the ambient data and upload it for display To facilitate system synchronization select the channel with the best signal and least interference for debugging C...

Page 21: ...on Enter the obtained phase difference value into Phase in Parameter Setting and click Set and Save If you observe that the noise and signal displayed by the channel signal are the smallest it means phase synchronization is completed Phase sync ...

Page 22: ...splays this record check whether the power supply is normal Settled New Parameter This record will automatically appear when you change the relevant parameter settings Function Key Clear Click Clear to clear the screen Query Click Query to upload the antenna record data and save the most recent 255 records at most Save Click Save to save the record to a specified file 3 4 2 5 Deployment Guidance o...

Page 23: ... About 1 m 2 m One primary antenna Channel widths About 2 m 4 m One primary and one replica antennas Channel widths About 4 m 6 m One primary and two replica antennas Channel widths About 6 m 8 m Two primary and two replica antennas ...

Page 24: ... About 8 m 10 m Two primary and three replica antennas By analogy one primary antenna can work with two replica antennas and the primary antenna can also work alone which can greatly meet the requirements of different channel widths ...

Page 25: ...pdates function to obtain timely information of firmware updates released by the manufacturer We suggest that you download and use the latest version of client software Nice to have recommendations to improve your device network security 1 Physical Protection We suggest that you perform physical protection to device especially storage devices For example place the device in a special computer room...

Page 26: ...nt or sensitive we recommend that you use encrypted transmission function to reduce the risk of audio and video data being stolen during transmission Reminder encrypted transmission will cause some loss in transmission efficiency 11 Secure Auditing Check online users we suggest that you check online users regularly to see if the device is logged in without authorization Check device log By viewing...

Page 27: ...User s Manual 22 Enable IP MAC address filtering function to limit the range of hosts allowed to access the device ...

Page 28: ......