![background image](http://html1.mh-extra.com/html/federal-signal-corporation/ss2000-plus/ss2000-plus_installation-and-operation-manual_3827536032.webp)
32
Using the S Software
Encoder/Decoder
Using the Activation Function Tab
Activation Function
The following shows the Activation Functions group box of the Activation Function tab.
Field
Description
Spin box—Button # Select the button to configure.
Function Name
Enter the name of the function. Symbols such as the equal sign =
and the semicolon ; are not allowed.
Activation Codes
• None—No activation code.
• TwoTone—Displays the TwoTone group box.
• DTMF—Displays the DTMF group box.
• EAS—Displays the EAS group box.
• Federal Digital (FSK)—Displays the Federal Digital group box.
• Relay Outputs—Displays the Relay Outputs group box.
• HotKey—Displays the HotKey group box. Only available with
Code #3. Activates Commander HotKey.
• SendRemoteInput—Displays the SendRemoteInput group box.
Only available with Code #3. Sends activation via radio to another
Commander encoder base station, which activates a function
dependent upon custom programming within the ss_input.ini file.
• Call Function Key#—Displays the Call Function Key# group box.
Only available with Code #3. Activates another activation HotKey
on the .
Mode
Select the mode of operation.
• AutoPromptSend—Activation is sent after user presses the
activation button and then the SEND button.
• AutoSend—Activation is sent after user presses the activation
button.
• AutoPromptSendAutoReport—Prompts the user to press the
SEND button after an activation button has been pressed before
initiating the activation. After the activation, the waits
the number of seconds indicated by Auto Report Delay and polls
the sites.
• AutoSendAutoReport—Initiates the activation immediately.
After the activation, the waits the number of seconds
indicated by Auto Report Delay and polls the sites.