Trouble Type Relay 2 Select
141 RELAY 2 TR x
NONE
Indicates the action taken for this Trouble Type on relay #2. Relay #2 is typically used for
smoke detector reset as defined in question 049. If smoke detector reset from the control
panel is not utilized and no zones are programmed for “Fire - Smoke” in question 143, then
the relay can be utilized for other applications . The options include:
NONE
PULSED
LATCHED
Press the 0 key to toggle between the available choices.
UL
For UL Listed systems this option shall be programmed "NONE".
After completion of this question the Trouble Type selection question (#129) will appear with
the next trouble type as the selected value. The only exception to this situation is after
trouble type 8 , and the display will advance to question 142.
To advance to any other programming question press
✴
STAY followed by the
desired question number.
Zone Definition
The zone definition section describes the attributes of the zones connected to the control
panel.
The control panel can be expanded using two methods of zone expansion: hardwired
expander (model 7105), or multiplex expansion module (model 7120 or 7126). The zones are
numbered as follows:
TOTAL
ZONES
EXPANSION
MODULE
XL-4, XL-4B, AND XL-5
BASIC HARDWIRED ZONES
XL-4 AND XL-4B
EXPANSION ZONES
XL-5
EXPANSION ZONES
8
NONE
1-8
NONE
NONE
16
7105
1-8
9-16
9-16
72
7120
1-8
9-72
N/A
128
7126
1-8
N/A
9-128
Each display contains a different zone attribute question. The zone number being defined is
indicated by the Zxxx notation in the right hand corner of the first line of the display.
IMPORTANT NOTES FOR MULTIPLEX ZONES
1- The zone numbers must be set within the multiplex device. This typically involves setting
of dip switches, consult the Installation Instructions for these devices for further
information.
2- Do not duplicate zone numbers of multiplex accessories. NOTE: The multiplex accessories
for multiple points (2 point and 8 point modules) will contain switch settings for the
starting address of the device. For example, an eight-zone module set with a starting
address of 9 will cover zones 9 - 16. This means that there should not be other devices
within the system within this range.
3- There are two separate methods to determine the points (zones) connected to the
multiplex bus. The options are described in the zone expansion module question # 031.
MUX EXPANDER 1 is an auto scan mode where the system will read the multiplex buss
and determine the valid addresses present upon reset (power-up or exit from programming).
Содержание XL-4
Страница 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Страница 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Страница 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Страница 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Страница 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Страница 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...
Страница 100: ...1 9 Al N9145V2 10 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset New York 11791 Copyright 1998 PITTWAY CORPORATION...