2–1
S E C T I O N 2
System Overview
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
General
♦
Partitions
♦
Zone
♦
Keypads
♦
Users
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
General
The system can be setup in a partitioned configuration. Partitioning allows the panel to look
like as many as 8 different protected locations to the Central Station. Each partition will be
assigned zones, users and keypads. The account numbers transmitted for each partition are
definable. Partitions can be setup to protect different functional areas of the same location
(example, office area vs. warehouse) or different premises within close proximity (example,
shopping center or multi family complex).
The control panel’s strong point is its flexibility. Zones, keypads, users, keypad functions,
relay outputs, CS monitoring and output triggers can be configured to satisfy a myriad of
security and monitoring applications. Unfortunately, flexibility breeds complexity; and,
unless a few basic things are understood, its programming can be confusing.
First, the control panel comes pre-programmed from the factory. The DEFAULT program is
listed in the System Defaults Section of this manual. You should be familiar with this
program so that each new program can be thought of as simply modifying the defaults. There
are numerous programming options but for standard applications, only a few of them need to
be changed. For example, to modify the system to operate as a local system with no CS
Reporting, set QUESTION #16 (CS Dialer Enable) to NO.
Second, sometimes the answer to many questions simply is not important. For example,
many CS reporting codes can be ignored if their respective question which controls its
reporting path is NONE. As another example, suppose a zone 's type is not selected to be an
Exit/Entry (programming question #143). Then, the Entry Delay selection (programming
question #165) has no bearing on that zone's operation.
Last, several system characteristics should be understood. The following definitions should
help in programming.
Partitions
As mentioned before, the system can be partitioned. This allows it to look like 8 different
systems. Partitioning is enabled by assigning zones, keypads and users to each partition
(questions #155, #180 and #028, respectively). Each partition can have its own account
number or they can all share the same account number for CS monitoring purposes
(questions #182 and #183). Each partition is independently armed and disarmed. In addition,
they can all be armed or disarmed at the same time by enabling two options (programming
questions #053 and #061).
Содержание XL-4
Страница 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Страница 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Страница 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Страница 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Страница 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Страница 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...
Страница 100: ...1 9 Al N9145V2 10 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset New York 11791 Copyright 1998 PITTWAY CORPORATION...