![FBII XL-4 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/fbii/xl-4/xl-4_programming-manual_3738648049.webp)
Section 8 - LCD Keypad Programming Questions
8–27
TO DISARM
Only multiple partition disarming is permitted.
TO ARM
Only multiple partition arming is permitted.
7 Digit User Code
062 USER# + CODE
NO
The control panel can be operated with either a four or seven digit user code. This question
indicates whether the user code required throughout the system will be the 4 digit user code
or the User # followed by the user code (seven digit). Default = NO
If YES, then a seven-digit entry will be required for all actions which require a user code. For
example, if user # 7 has a user code of 1234 then that user would enter 0071234 to perform
actions on the system.
This option affects all users for all partitions. Press the 0 key to toggle between the available
choices.
Default Lockout Option
063 CS/INST DEF
YES
This option is known as the default lockout option and determines whether the CSID and
Installer Code will be modified upon initiating a system default. To obtain default lockout
protection, answer NO to this question.
If the Default Lockout option is selected then a system default will reset all of the
programmable options except the CSID and the Installer Code. Press the 0 key to toggle
between the available choices.
Keypad Programming
064 KPAD PROG
YES
This question indicates whether keypad programming will be enabled. If keypad
programming is disabled then the system can only be programmed through the EZ-Mate PC
Software package.
If this question is answered as NO you will be unable to reenter keypad programming.
Default = YES. Press the 0 key to toggle between the available choices.
Daylight Savings Time
065 DAYLITE SAV
NO
Indicates whether this location observes daylight savings time. If YES then the system will
automatically switch the time when appropriate each season. Press the 0 key to toggle
between the available choices.
AC Line Frequency
066 AC FREQ
60 HZ
Indicates the line frequency of the incoming AC power line. The choices are 60 Hertz or 50
Hertz [Default = 60 HZ]. The 0 key will toggle between the choices of 60hz and 50hz. This
Содержание XL-4
Страница 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Страница 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Страница 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Страница 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Страница 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Страница 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...
Страница 100: ...1 9 Al N9145V2 10 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset New York 11791 Copyright 1998 PITTWAY CORPORATION...