XL-4, XL-4B, and XL-5 LCD Keypad Programming Manual
Version 4
8–14
Ring Count
022 # RINGS
08 (01-16)
Whenever the Alarm Company attempts to communicate remotely with the system it will
dial the telephone number attached to the control panel. This question determines how many
rings are necessary for this control panel to pickup. NOTE: After the first ring the control
panel will listen into the telephone line to determine whether there is an EZ-Mate
downloader present. If the downloader is present then the control panel will pick up the line,
after the ring count has occurred.
The number of rings should be selected not to interfere with normal operation of the
protected premise. For example, if the system were connected to the existing telephone line
of the location a value of one ring for pickup would probably be undesirable since the panel
would pickup and seize the telephone line every time the premise telephone would ring.
If an answering machine is present at the control panel site, then the number of rings should
be set greater than the number of rings for the answering machine to pickup.
Default value = 8.
Extended Antijam Time
023 EXT ANTIJAM
NO
The control panel contains an anti-jam feature before it performs any communicator dialing.
The anti-jam feature will disconnect the internal telephone line and perform a hang-up on
any external connection. The standard hang-up time is 4 seconds, and the extended option
will hang up for 30 seconds prior to dialing.
The anti-jam time represents the amount of time that the panel will wait between the time
that the dialer has seized the line to the time that the dialing begins.
The anti-jam sequence will be utilized if dial tone detection is not selected or if dial tone
detection is selected and dial tone is not present at the time of dialing (see question 015).
Default = NO.
Extended Acknowledgment
024 EXTENDED ACK
NO
Indicates whether the panel should wait up to 120 seconds for an acknowledgment from the
Central Station receiver, otherwise the panel will wait 30 seconds. Press the 0 key to toggle
between the available choices. Default = NO.
UL
This option must be programmed as "NO" for UL Listed Systems.
User Definition
The XL-4 and XL-5 control panels contain up to 64 user codes while the XL-5 contains up to
128 user codes. Each user has a unique four-digit user code, an authorization code, partition
assignments, open/close assignments, and a master partition. This section of the Installer
keypad programming is used to setup the authorization levels and user partition
assignments within the panel.
Содержание XL-4
Страница 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Страница 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Страница 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Страница 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Страница 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Страница 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...
Страница 100: ...1 9 Al N9145V2 10 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset New York 11791 Copyright 1998 PITTWAY CORPORATION...