Section 8 - LCD Keypad Programming Questions
8–11
CS#2 Account Size
010 CS2 ACC SIZE
4 DIGIT ACC
This question indicates whether a three or four digit account number will be transmitted to
CS#2. Depression of the 0 key will toggle between 3 and 4-digit account size. If a three-digit
account number is selected then any fourth digit will be ignored.
This question will be skipped if there is no transmission to CS#2 (question 008).
The FBI Superfast, 4x2 Express, and ADEMCO PID (point ID) formats utilize a four-digit account
number.
The actual account number transmitted to the secondary CS is defined in question 183.
CS#2 Parity Selection
011 PARITY CS2
YES
Enter the desired parity setting for CS#2 transmissions. Parity is an error detection scheme
that is used in certain CS transmission formats. If you are unsure about the parity setting
for your receiver please contact your Central Station manager.
This question will be skipped if signals are not transmitted to CS#2 (question 008).
Sescoa Format
CS#2
012 SESCOA
NO
This question indicates whether the Sescoa format for fixed digit timing will be transmitted
to CS#2. NOTE: This only applies to the various pulse based CS transmission formats and
will be skipped if there is no telephone number defined for CS#2 (question 008).
UL
This option shall not be used for UL listed systems. This question will be skipped if signals are
not transmitted to CS#2 (question 008).
Panel Installer Code
013 INSTAL CODE
123456
The system contains a series of functions that can only be performed by an authorized
installer. These functions include keypad programming, walk test, time setup, and system
log view.
In order to perform any of these installer reserved functions entry of this six-digit installer
code will be necessary. Each alarm company should select a six-digit code in order to secure
their panels from other installers. The code should probably be kept uniform for each Alarm
company. The factory default value for the installer code is 123456. Note: If the default
lockout option (Question #063) is selected then this value will not be overwritten with a
system default. To erase the installer code press
✴
8.
Содержание XL-4
Страница 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Страница 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Страница 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Страница 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Страница 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Страница 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...
Страница 100: ...1 9 Al N9145V2 10 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset New York 11791 Copyright 1998 PITTWAY CORPORATION...