6. EtherCAT Object Dictionary
6.6.7
Object 2008h: Boost current
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
2008h
0
Boost current
U8
RW
Yes
No
0
∼
7
0
This Object sets the current value (Boost current) to be added when the motor accelerates or decelerates.
Boost current
[%] =
Value
×
50
Boost current is applied propotional to the value of Run current. For example, if you use the EzM2-42XL
(rated current: 1.2[A]), the Run current is 8 (80[%]) and the Boost current is 1 (50[%])), the control current
value during acceleration or deceleration is as follow.
Control Current value
[
A
] =
Rated Current
[
A
]
×
Run current
[%]
×
(100[%] +
Boost current
[%])
= 1
.
2
×
80[%]
×
(100[%] + 50[%])
= 1
.
2
×
120[%]
= 1
.
44[
A
]
Boost current is a setting that improves the accel./decel. characteristics by increasing the current sup-
plied to the motor in case the accel./decel. time cannot be set sufficiently. Boost current only applies to
acceleration and deceleration.
Information
• If Boost current value is high, the heating temperature of a motor can be increased. So please
be careful.
• The control current is limited to 4[A] same as Run current. Therefore, a motor(56mm, 60mm)
that rated current value exceeds 2.7[A] will not increase as much as the set value even if the
set value is raised.
Information
This object can NOT be set while it’s ’Operation Enabled’ state. Please set after ’Operation Disable’.
Please refer to
6.6.8
Object 2009h: Stop current
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
2009h
0
Stop current
U8
RW
Yes
No
2
∼
10
5
This object sets the Stop current when the motor is stopped and there is no load.
Stop current
[%] =
Value
×
10
Stop current is applied propotional to the value of Run current. For example, if you use the EzM2-42XL
(rated current: 1.2[A]), the Run current is 8 (80[%]) and the Stop current is 5 (50[%])), the control current
value when the motor is stopped.
Control Current value
[
A
] =
Rated Current
[
A
]
×
(
Run current
[%]
×
Stop current
[%])
= 1
.
2
×
(80[%]
×
50[%])
= 1
.
2
×
40[%]
= 0
.
48[
A
]
The drive adjusts the motor’s drive current from Stop current to Run current according to the size of the
load. This setting is used to reduce heat generation when the motor is stationary or when the load is
light.
Rev.37
FASTECH Co., Ltd.
85
Содержание Ezi-STEPII EtherCAT MINI
Страница 1: ...Open Loop Stepping System EtherCAT Network User Manual Ezi STEPII EtherCAT MINI FASTECH Co Ltd ...
Страница 10: ...Chapter 1 Product Specification Rev 37 FASTECH Co Ltd 10 ...
Страница 14: ...Chapter 2 Installation Rev 37 FASTECH Co Ltd 14 ...
Страница 25: ...Chapter 3 EtherCAT Communication Rev 37 FASTECH Co Ltd 25 ...
Страница 31: ...Chapter 4 CiA402 Drive Profile Rev 37 FASTECH Co Ltd 31 ...
Страница 55: ...Chapter 5 Operation Rev 37 FASTECH Co Ltd 55 ...
Страница 59: ...Chapter 6 EtherCAT Object Dictionary Rev 37 FASTECH Co Ltd 59 ...