![Fastech Ezi-STEPII EtherCAT MINI Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/fastech/ezi-stepii-ethercat-mini/ezi-stepii-ethercat-mini_user-manual_546254078.webp)
6. EtherCAT Object Dictionary
6.5.32
Object 60C2h: Interpolation time period
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
60C2h
0
Number of entries
U8
RO
No
No
2
1
Interpolation time period
value
U8
RW
Yes
No
0
∼
255
2
2
Interpolation time index
I8
RW
Yes
No
-4
∼
1
-3
This object indicates and sets cycle time using at synchronous control mode (for example : Cyclic Syn-
chronous Position Mode)
cycle time
[sec] =
Interpolation time period value
×
10
Interpolation time index
Information
If uses DC mode for method of synchronization, cycle time ignores set value as above and auto-
matically uses Sync0 cycle time.
6.5.33
Object 60D0h: Touch probe source
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
60D0h
0
Number of entries
U8
RO
No
No
2
1
Touch probe 1 source
U16
RW
No
No
1
2
Touch probe 2 source
U16
RW
No
No
1
If the value of Bit 2
∼
3, 10
∼
11 for Touch probe function (60B8h) as 2, uses input signal already set at
this Object.
Value
Input Source
1
Origin Switch
2
User Input 1
3
User Input 2
Table 6.26: Touch probe 1 source
Value
Input Source
1
Origin Switch
2
User Input 3
3
User Input 4
Table 6.27: Touch probe 2 source
6.5.34
Object 60D5h: Touch probe 1 positive edge counter
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
60D5h
0
Touch probe 1 positive edge
counter
U16
RO
No
TxPDO
0
This object displays the number of times the rising edge of Touch Probe 1 is detected.
6.5.35
Object 60D6h: Touch probe 1 negative edge counter
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
60D6h
0
Touch probe 1 negative edge
counter
U16
RO
No
TxPDO
0
This object displays the number of times the falling edge of Touch Probe 1 is detected.
6.5.36
Object 60D7h: Touch probe 2 positive edge counter
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
60D7h
0
Touch probe 2 positive edge
counter
U16
RO
No
TxPDO
0
This object displays the number of times the rising edge of Touch Probe 2 is detected.
Rev.37
FASTECH Co., Ltd.
78
Содержание Ezi-STEPII EtherCAT MINI
Страница 1: ...Open Loop Stepping System EtherCAT Network User Manual Ezi STEPII EtherCAT MINI FASTECH Co Ltd ...
Страница 10: ...Chapter 1 Product Specification Rev 37 FASTECH Co Ltd 10 ...
Страница 14: ...Chapter 2 Installation Rev 37 FASTECH Co Ltd 14 ...
Страница 25: ...Chapter 3 EtherCAT Communication Rev 37 FASTECH Co Ltd 25 ...
Страница 31: ...Chapter 4 CiA402 Drive Profile Rev 37 FASTECH Co Ltd 31 ...
Страница 55: ...Chapter 5 Operation Rev 37 FASTECH Co Ltd 55 ...
Страница 59: ...Chapter 6 EtherCAT Object Dictionary Rev 37 FASTECH Co Ltd 59 ...