2. Installation
Type of Status Indication
EtherCAT LED Status Indication shown as picture as below to check visually.
Figure 2.5: EtherCAT LED
2.4.2
EtherCAT Communication Connection
Connect communication cable from Master into communication connection ECAT IN. If there is next
controller, connect communication cable from ECAT OUT to next controller of ECAT IN.
No.
Function
1
TD+
2
TD-
3
RD+
4
RD-
5
F.GND
Table 2.2: EtherCAT Connector
EtherCAT Communication Cable
Recommend to use communication cable Min. CAT5e level above.
• CAT5e or above
• Shield type : SF/FTP, S/FTP, SF/UTP
• Length : Max. 50m (Distance between Nodes)
Rev.37