4. CiA402 Drive Profile
Touch Probe Operation : Continuous signal acknowledgement
If Touch probe function of bit number 1, 9 has set as 1, Touch probe uses all acknowledged signals after
Enable.
Please refer to Timing chart as follows.
Figure 4.13: Touch Probe Operation (Bit 1 / Bit 9 = 1)
Touch probe status of bit number 6
∼
7, 14
∼
15 (Counter) value increases every single of input signal
acknowledgement. (Range of this value is 0
∼
3.)
For the frequency of input signal acknowledgement, please check Touch probe 1 positive edge counter,
Touch probe 2 positive edge counter, Touch probe 1 negative edge counter, Touch probe 2 negative
edge counter.
Rev.37