IL3 User’s Guide
11S-3002B
page 47
Pass Thru
When you select Sync Out Pass Thru, the signal
received on Sync In is sent to Sync Out. The only
setting that affects this signal is the Invert Sync In
option, which simply inverts the signal.
5-3 Master/Slave Setup
There are many possible configurations used to
synchronize groups of cameras. The Master/Slave
configuration is often used when a group cameras
is used to capture multiple synchronous views of an event that is not driven by a clock or PLC. For
example, when studying animal or human kinetics, the subject (animal or human) is not supplying
a sync signal for the camera system, so the camera system uses its own: Sync Out from a Master
camera.
In this configuration, any camera may be used as the Master.
Commonly, all cameras are set to the same Frame Rate and Resolution, are triggered together, and
integrate frames together (synchronize frame start times). For this setup:
•
Enable External Trigger for all cameras and use the same polarity for all.
•
Sync Out from the Master camera is set to “Per Frame”
•
Sync Out for the Slave cameras are set to “Pass Thru.” Invert Sync In is
not
selected.
•
Sync In for the Slave cameras Master Frame rate is set the same as the Frame rate of the Master
camera.
•
Choice of Shutter or Duty Cycle does not matter.
Figure 5-6: Sync Pass Thru