Connect an air hose or hard plumbing from the compressed air source to the 1” NPT coupling on either
side of the header (¾” minimum air supply line for GS2 – GS10, 1” supply line for anything larger than a
GS10). A shut-off valve is recommended between the compressed air source and the header.
Slowly
open the shut-off valve, allowing pressure to build in the tank.
When the header has reached full line pressure of 90 to 105 psi, close the shut-off valve.
Inspect the header, valves, fittings and solenoid valves for air leaks.
Tighten all fittings and clamps as required.
Re-open the air shut-off valve.
22
Gold Series Dust Collector Air Consumption -
1" Diaphragm Valve
0
10
20
30
40
0
10
20
30
40
50
60
70
OFF TIME (sec)
C
o
m
p
re
ssed
A
ir
C
ons
u
m
p
ti
on (
C
FM
)
200 msec ON TIME
150 msec ON TIME
100 msec ON TIME
100
150
200
100
150
200
5
27.0
31.8
37.2
38.4
72.0
92.4
10
13.5
15.9
18.6
19.2
36.0
46.2
15
9.0
10.6
12.4
12.8
24.0
30.8
20
6.8
8.0
9.3
9.6
18.0
23.1
25
5.4
6.4
7.4
7.7
14.4
18.5
30
4.5
5.3
6.2
6.4
12.0
15.4
35
3.9
4.5
5.3
5.5
10.3
13.2
40
3.4
4.0
4.7
4.8
9.0
11.6
45
3.0
3.5
4.1
4.3
8.0
10.3
50
2.7
3.2
3.7
3.8
7.2
9.2
55
2.5
2.9
3.4
3.5
6.5
8.4
60
2.3
2.7
3.1
3.2
6.0
7.7
Table 330.5.1
Gold Series Dust Collector Air Consumption
(For any size GS collector based on diaphragm size)
1-1/2" Diaphragm Valve
On Time (msec)
Compressed Air Consumption (ft
3
/min.)
1" Diaphragm Valve