320.2 Inlet Flanges
Depending on the size and orientation of your
Gold Series
collector, the inlet will have one or more of
three inlet designs. These inlets are configured and classified with the number of modules that the
collector uses to support the inlet plenum. Larger collectors may have more than one inlet plenum
and vary in the size of the inlet. Figures 320.1, 320.2 and 320.3 show dimensions of the one, two, and
three module inlets respectively. When attaching ductwork to these flanges always be sure to caulk or
place gasket material between the duct and collector before bolting them together.
320.3 Remote Mount Fan Discharges
Remote mount fans, provided by Farr, will be ducted to the collector by removing an upper panel and
attaching the ductwork to the frame of the
Gold Series
dust collector. The ductwork will be attached to
the flange details on Figures 320.4-320.7. These dimensions are the bolt patterns for the panel and
frames. Either the side panels, on the upper section of the dust collector, or top panels can be
removed. Figure 320.4, is the bolt pattern for the full sized side panel, while Figure 320.5, is for the
half sized side panel. Figure 320.6 and 320.7 are for the full and half sized top panels respectively.
When attaching ductwork to these flanges, always be sure to caulk or place gasket between the duct
and collector before bolting them together.
320.4 Top Mount Fan Discharges
Top mount fans, provided by Farr, are field mounted on the top of the
Gold Series
collector. All Farr
provided fans will have a fan damper supplied with the fan. When attaching ductwork to this flange,
always be sure to caulk or place gasket between the duct and damper outlet before bolting them
together.
320.5 Discharge Hopper Flange
Accessories will be attached to the hopper discharge flange. See your General dimensions drawing for
the dimensions for your flange.
16
DUCT DIA.
DUCT DIA.
DUST
PARTICLES
GS 16 SHOWN
INLET
DUST
PARTICLES
RECOMMENDED
NOT RECOMMENDED
TRANSITION
Figure 320.9 - Top View
TR
AN
SIT
ION
SL
OP
E
60°
MI
N.
DUCT LENGTH
MIN 2X DIAMETER