39
VALUE
WHEN DISABLED THE IDC CAN PULSE CLEAN BASED
ON DP SETTINGS OR CONTINUOUSLY CLEAN. ATTACH
A JUMPER TO SHORT THE BYPASS INPUT TO PULSE
CONTINUOUSLY. (SEE BOARD SCHEMATIC)
Y
CYCLE DOWN
MODE
ACCEPT
N
SELECT "M" AND ENTER THE NUMBER OF
SOLENOIDS HOOKED TO TIMER IN NEXT STEP
SELECT "A" AND THE DEVICE COUNTS THE SOLENOIDS
ATTACHED TO TIMER - WHEN "A" IS SELECTED THE
OUTPUT FAULT DETECTION FEATURE IS ACTIVATED
CHANGE
SKIP
LAST = X
M = MANUAL
A = AUTO
ITEM DN FOR NEXT OPTION
M
OUTPUT = ?
ACCEPT
A
SOFTWARE VERSION - CANNOT BE CHANGED. MUST
BE COMPATIBLE WITH SOFTWARE VERSION OF I/O
CARD AND REMOTE ANUNCIATOR WHEN USED.
DISPLAYS LAST OUTPUT TRIGGERED
DO YOU WANT TO ENTER PROGRAM MODE?
PRESS VALUE KEY FOR YES - PRESS ITEM UP KEY
SEVERAL TIMES TO RETURN TO OPERATING MODE
PROGRAM IDC
DO YOU WANT PROGRAM THE
INTELEGENT DUST CONTROL?
PRESS VALUE KEY FOR YES
-PRESS ITEM DOWN ITEM KEY
TO ADVANCE TO NEXT OPTION.
YES
NO
YES
VERSION = X.X
NO
PROGRAM
PROGRAM I/O
DO YOU WANT PROGRAM THE I/O BOARD? PRESS
VALUE KEY FOR YES - PRESS ITEM DOWN KEY TO
ADVANCE TO NEXT OPTION. NOTE: I/O BOARD MUST
BE CONNECTED OR ERRORS WILL BE DISPLAYED.
YES
NO
DISPLAY FREEZES AT P = X.X
OPERATING MODE
DISPLAYS SETUP ON STARTUP AND AFTER RESET
DISPLAYS P = X.X WHEN RUNNING
OUTPUT = X
EXIT
DO YOU WANT EXIT PROGRAM MODE?
PRESS VALUE KEY FOR YES - PRESS
ITEM UP KEY TO MOVE BACK TO
PREVIOUS OPTIONS
DO YOU WANT PROGRAM THE CLOCK?
(REQUIRES I/O BOARD) PRESS VALUE
KEY FOR YES - PRESS ITEM DOWN KEY
TO ADVANCE TO NEXT OPTION.
PROGRAM CLK
YES
NO
YES
NO
ITEM
ITEM
VALUE
ITEM
ITEM
ITEM
ITEM
ITEM
ITEM
ITEM
ITEM
ITEM
ITEM
ITEM
VALUE
VALUE
VALUE
VALUE
ITEM
ITEM
VALUE
VALUE
VALUE
ITEM
VALUE
VALUE
ITEM
OUTPUT
STEP
ALARM
CANCEL
Display Keypad
Use the Item Keys to:
1) Navigate within the
Programming Tree
The Key moves up the Tree
The Key moves down the Tree
Use the Value Keys to:
1) Select Program Options
2) Change parameters
The Key increments value
The Key decrements value
VALUE VALUE
ITEM
VALUE
VALUE
ITEM
ITEM
ITEM
ITEM
"B"
"C"
"A"
CONSULT FACTORY
FOR PROGRAMMING
INSTRUCTIONS
USE VALUE UP AND DOWN
KEYS TO CHANGE SETTINGS
Y = ENABLE
N = DISABLE
WHEN ENABLED, THE BYPASS INPUT (SEE BOARD
SCHEMATIC) SHOULD BE CONNECTED TO DRY
CONTACTS THAT OPEN WHEN THE FAN IS TURNED
OFF. THE IDC WILL PULSE CLEAN BASED ON DP
SETTINGS WHEN FAN IS ON. WHEN FAN IS TURNED
OFF THE IDC WILL CYCLE THROUGH A BLOW DOWN
MODE BASED ON SETTINGS WHICH FOLLOW.
TELL IDC HOW MANY SOLENOIDS
ARE ATTACHED - SKIP IF
OUTPUT = A