mount fan
,
remove the upper side panel from the side you intend to make your fan duct flanged
connection. Remove any old rope caulk that did not come off with the upper side panel.
Clean the fan flange and apply rope caulk, ensuring a continuous seal.
If you have a top mount fan, lift the fan onto the filter module roof. Bolt the fan to the fan mount panel
using the hardware included –Figure 310.1. If you have a remote mount fan refer to section 320 (Remote
mount fan discharges) for further instructions.
Remove any dirt or other accumulation from the hopper flange. Line the hopper flange with rope caulk as
indicated in Figure 310.3. Ensure that there is a continuous seal on the flange.
Lift the filter module, using the lifting lugs provided and approved lifting equipment – Figure 310.3. Failure
to connect lifting cable to all (4) lifting lugs may result in damage to the collector. On larger collectors,
adequate cable length or a spreader bar is required to prevent damage to the collector.
Clean the filter module flange and set onto the hopper flange, taking care not to damage the flanges or
rope caulk. Ensure that the orientation of the collector is as desired for your installation.
Note: On GS6,
10 & 20 collectors ensure that the “Match Line” label(s) on the filter module, line up with the
“Match Line” label(s) on the hopper(s) - Figure 310.3.
Attach the filter module to the hopper, using 3/8-16 thread cutter screws – Figure 310.3. Use a drift or
alignment pin to align holes as necessary. Insert bolts into each of the four corners without tightening
them. Insert the bolts from the corners to the center of the collector.
Note: Do not tighten bolts when
starting to align hopper. Wait until all bolts have been started before tightening.
Keep most of the
weight on the crane or forklift supporting the filter module. This will allow you to move and adjust the filter
module as necessary.
310.6 Discharge Accessories
Locate the hopper discharge accessory supplied with your collector. This will be a drum kit/slide gate,
rotary airlock or screw conveyor. Install the accessory to the hopper discharge flange(s) using the
General Dimensions drawing and Section 320 as a guide.
12
CORNER SUPPORT
BRACKET
5/8 BOLT
5/8 FLAT WASHER
5/8 LOCK WASHER
5/8 NUT
FIGURE 310.2
(GS 32 SHOWN)
5/8" BOLT, FLAT WASHER
(2 SIDES), LOCK WASHER &
NUT (TYP ALL CONNECTIONS)
SLOT FOR
LIFTING
KNEE BRACE