background image

May vary slightly in appearance.

Shown with optional Mobile Cart 

and 17 Gal. Drum.

Oneida Air Systems, Inc.  1001 West Fayette St., Syracuse, NY 13204

Phone 1.800.732.4065  315.476.5151  Fax 315.476.5044  www.oneida-air.com

Owner’s Manual

1-10

ZBM000024

TM

U.S. Design Patent 

No. D604,464

XXP010101

XXP010100

Содержание Mini GORILLA XXP010100

Страница 1: ...onal Mobile Cart and 17 Gal Drum Oneida Air Systems Inc 1001 West Fayette St Syracuse NY 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual 1 10 ZBM000024 TM U...

Страница 2: ...collection Call for ductwork design and ductwork quotes including system pricing and shipping cost Read the entire Owner s Manual before installing or operating system Proudly Made in the USA I II II...

Страница 3: ...Handling and installation should always be performed by healthy individuals Additional help may be re quired In addition to the following instructional manual care should be taken to ensure complianc...

Страница 4: ...st be taken not to damage the membrane If there is significant backside blinding compressed air may be used However forcing the dust further into the media from the backside is likely Wahing the filte...

Страница 5: ...00001 3 Thumb Nut 5 16 x 18 AFT025200 4 Nut 1 4 20 U Spring AFT155175 6 Whiz Lock Nut 5 16 AFW025000 4 Washer Flat USS 1 4 AFW180000 12 Washer Flat USS 5 16 RCP050000 1 Silicone Plug 438 x 687 x 1 RGZ...

Страница 6: ...5 Mini Gorilla Owner s Manual O A S 2010 c V Dimensions Approx 39 Approx 15 Width with Filter Approx 29 Width with Filter Mobile Cart Approx 36 Approx 62...

Страница 7: ...bracket are heavy Make sure the bracket is level when it is attached 3 The collector can only be attached to the wall bracket with the cyclone inlet in front as shown in picture Line up the holes in...

Страница 8: ...Motor and Cyclone 3 Attach the Magnetic Starter to a leg with supplied clamps with bolts if you have the mobile cart or a sturdy surface if you are wall mounting it 3 6 Attach filter to plate as shown...

Страница 9: ...en put on wheel washer through the eye bolt washer then through the tubes on the bottom of the tray as shown in diagram below then repeat on the other side 2 Before you attach the legs to the bracket...

Страница 10: ...if equipped with slot ted grease screws If motor has a purge plug remove it Motors can be re greased while stopped at less than 80 C or running Apply grease gun to fitting or grease hole Too much grea...

Страница 11: ...n Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check for a restricted pipe too small a hood port or too small a branch l...

Страница 12: ...t requires an aggregate dust collection flow rate of more than 1500 cfm cubic feet per minute This exempts some small operators from the NFPA code 664 but other codes may apply in your jurisdiction Co...

Страница 13: ...neida Air Systems shall in no event be liable for death injuries to persons or property or for incidental contin gent special or consequential damages arising from the use of our product Oneida Air Sy...

Отзывы: