71
Alarms (3)
4.
Auto Reset: Select to toggle between Automatic and Manual.
a.
Automatic: The Alarm will automatically reset once it is no longer in the Alarm state; the
user will not have to select the Reset button to reset.
b.
Manual: The Alarm will not reset once it is no longer in the Alarm state; the user will have
to select the Reset button to reset.
5.
Alarm Buzzer Period: Select to input a numerical value.
a.
Enter a value in seconds for how long the audible warning will sound.
NOTE:
This is only the audible warning; the visual warning will last until reset.
6.
Min Set Point: Select to toggle between On and Off.
a.
On: When the value of the Alarm drops below the given Min Value it will go into the Alarm
state.
b.
Off: When the value of the Alarm drops below the given Min Value it will not go into the
Alarm state.
7.
Min Value: Select to input a numerical value.
a.
Input the minimum value for the Alarm.
8.
Max Set Point: Select to toggle between On and Off.
a.
On: When the value of the Alarm goes above the given Max Value it will go into the Alarm
state.
b.
Off: When the value of the Alarm goes above the given Max Value it will not go into the
Alarm state.
9.
Max Value: Select to input a numerical value.
a.
Input the maximum value for the Alarm.