Machine Setup
CANBUS (4)
The CANbus menu allows you to confirm the connection status and voltage to the UniPOD along with
smart switch and remote Run/ Hold switch if attached. If multiple UniPODs are attached to the 7000
system, the order of the pods can be configured here also.
The 7000 should automatically detect the UniPOD connected to the 7000. If not, follow the steps below.
CONFIGURE UNIPODS (4A)
The Configure UniPOD menu will display the unique CAN ID’s for each UniPOD connected. If more than one
UniPOD is connected, the order in which they are physically connected on the wiring harness must be
aligned to how the software has them connected.
1.
Navigate to the Settings > Machine > CANbus menu.
2.
Select UniPOD’s
3.
Select Configure UniPOD’s
4.
Select UniPOD #1. This will display all the UniPOD ID’s the system has been connected to.
5.
Select the UniPOD ID of the UniPOD connected first on the physical wiring harness
6.
Select the green Tick button to save changes.
If more than one UniPOD is installed then repeat this procedure for each extra UniPOD.